    Technical service

    Techcon TS250/TS350 Glue Dispensing Machine User Manual

    Release Date:2017-07-25

    TechconTaikang TS250/TS350 Glue Dispensing Machine User Manual


    TS250/TS350DispenserSafety NoteImportant matters:

    1.Do not exceed the maximum rated power when operating this device/set up

    2.Be sure to wear appropriate personal protective clothing

    3.Only the following power adapter models can be used:PSA15R-240P(ZJ)orPW118RA2403B01ThePW118RA2403H01ThePW118RA2403M01ThePW118RA2403G01

    4.Be careful to prevent corrosive or flammable liquids from flowing back into the equipment at the entrance. If corrosive or flammable liquids are used, an intake pipe filter must be installed on the dispensing machine(881-000-000)To prevent liquid from being sucked back into the equipment

    5.Glue may be toxic and/Or hazardous substances. Please carefully read the "Material Safety Data Sheet" and safety regulationsmatters needing attention

    6.If the piston is not used in conjunction with the syringe, an intake pipe filter must be installed on the receiver head(881-000-000)To prevent liquid from being sucked back into the equipment. Do not overfill the syringe and use itSide placement

    7.Do not smoke or use open flames when dispensing flammable liquids

    8.This device can only be used indoors
    6.JPG

    6.1 Manual/Glue dispensing cycle setting:

    1. Press the 'Power' button(1)Open the device.

    2. Press the 'Mode' button(2)Until it appears on the monitor“PURGERemove the glue.

    3. By rotating the pressure adjustment knob(5)Until the required dispensing pressure is displayed

    4. After filling the syringe or using pre packaged adhesive, attach the syringe to the receiver head assembly. Ensure that the syringe is fixed in the appropriate position.

    5. Connect the insertion end of the receiver head assembly to one of the pneumatic dispensing outlets(6).

    6. If vacuum suction is required, rotate the vacuum pressure knob counterclockwise(7)The required vacuum pressure can be displayed.

    7. Press the foot switch to activate the dispensing cycle. (Manually at this moment)/The glue dispensing mode is activated


    6.2 Automatic dispensing cycle setting

    6.2.1Program selection

    1.Press the settings button(3)Until“P:”Start flashing

    2.Rotate program selection button(8)Select the required program

    6.2.2time setting

    1.Press the mode button(2)Select the desired time mode

    2.Press and release the settings button(3)Until time(:)Start flashing.

    3.Rotate the time knob(8)Select the required dispensing time

    4.Press the foot pedal switch to start the dispensing cycle


    6.3 Training mode setting

    In training mode, as long as the foot switch is pressed down, the device will accumulate time. This helps determine the necessary dispensing time when the dispensing output is unknown.

    1. Press the mode button(2)Select training mode.

    2. Press and release the settings button(3)Until the dispensing time= 0.000S

    3. Press the 'foot pedal' switch. During this operation, the dispensing time will accumulate continuously.

    4. When the dispensing reaches the appropriate amount, release the "foot pedal" switch.

    5. Press and hold the 'Settings' button(3)continued 2 Save data in seconds.

    6. Press the 'Mode' button(2)Convert to“TIMED(Continuous) mode.

    7. At this moment, the dispensing machine is set to repeat this cycle.


    6.4 Continuous dispensing program settings:

    TS350/TS355Can store up to 10 Apply adhesive independently or continuously.

    1. according to 6.2 Select the automatic dispensing time in the required program for the steps.

    2. Simultaneously press the settings button(3)And the power button(1)Start a continuous dispensing program.

    3. Press and hold the settings button(3)Maintaining TimeSeconds, can save the program for continuous dispensing.

    The dispensing machine now saves the continuous dispensing program.

    4. Press the mode button(2)Exit the continuous dispensing program.


    6.5 Cyclic counter

    The cycle counter records the number of activated automatic dispensing cycles. The maximum number of cycles that can be recorded is65,535Article. This number is displayed on the LCD monitor(LCD)The bottom right corner. In order to clear the meterNumber, you can hold down the settings button at the same time(3)And mode button(2)Until the counter is“0.


    6.6 Adjust the dispensing pressure and vacuum pressure display

    1. Press and release the settings button(3)until(:)Flashing on dispensing pressure and vacuum pressure

    2. Rotate the time knob(8)Select the desired display value


    Troubleshooting of TS250/TS350 Glue Dispensing Machine

    fault

    Possible reasons

    Troubleshooting methods

    LCDNot lit up

    ? Not powered on

    Check the power cord connection
    ? Turn on the power

    The system cannot start

    ? The 'foot pedal' switch is not connected or the plug is not inserted correctly
    There is an issue with the foot switch
    The internal wiring of the device is damaged or the connection is not secure
    There is a problem with the solenoid coil
    ?PCThere is a problem with the board

    Check the connection of the foot switch
    ? Repair or replace the foot switch
    Unplug the power cord and disconnect the air source. Remove the cover and check for damaged wires or loose connections
    ? Replace the solenoid coil
    ? ReplacePCplate

    The system cannot boost the pressure

    ? Insufficient air pressure
    The air hose is not connected
    There is a problem with the regulator

    ? Increase the pressure of the gas source
    ? Check the connection
    ? Replace the regulator

    The system cannot be evacuated

    The vacuum setting is too low
    There is a problem with the solenoid coil
    There is an issue with the vacuum Venturi tube
    There is a problem with the vacuum needle valve

    ? Increase the vacuum setting
    Replace the solenoid valve
    ? Replace the Venturi tube
    Replace the needle valve

    Inconsistent glue dispensing

    There are bubbles in the adhesive
    The dispensing time is too short
    At the beginning, the dispensing needle is blocked

    ? Reduce the vacuum setting
    ? Extend the dispensing time
    ? Replace the needle


    TS250/TS350 Glue Dispensing Machinemaintain

    This dispensing machine has become increasingly sophisticated in both design and manufacturing, greatly reducing maintenance requirements. To ensure trouble free operation, please follow the following recommendations:

    1. Ensure that the gas source is clean and dry.

    2. Avoid reversing or placing the syringe flat, as this may cause liquid to pass through the gas pipeline and enter the internal components.

    3. Avoid connecting the equipment to gases or saturated solutions with excessive humidity.

    4. Avoid exceeding the pressure of the connected gas sourceTS350The prescribed100 psi6.9 Ba) andTS355The prescribed15 psi1.03 Ba).

    5. Only use pentanol to clean the outer surface of the mainframe.

    6. Wipe the LCD monitor with only soft fabric(LCD).


    展開
    亚洲精品99久久久久中文字幕| 北条麻妃在线视频观看| 亚洲国产成人va在线观看| 91天堂素人精品系列网站| 国产三级在线观看免费| 久久夜色精品国产嚕嚕亚洲av| 国产一区中文字幕| 欧美人善交videosg| 久久精品免费视频观看| 视频一区在线免费观看| 亚洲精品在线网站| 2022久久国产精品免费热麻豆| 亚洲成av人片不卡无码| 国产精品一区12p| 免费人成在线观看网站品爱网日本| 精品久久伦理中文字幕| 性调教室高h学校小说| 出轨的女人hd中文字幕| 99在线精品免费视频| 国产丝袜第一页| 丁香六月纪婷婷激情综合| 国产做无码视频在线观看| 窝窝午夜看片七次郎青草视频| 久草免费手机视频| 国产真乱全集mangent| 求网址你懂你的2022| 中文字幕羽月希黑人侵犯| 狠狠做深爱婷婷综合一区| 国产精品久久久久久搜索| 欧产日产国产精品| 麻豆第一区MV免费观看网站| 亚洲国产成人久久一区www| 麻豆视频免费观看| 日韩精品福利视频一区二区三区| 2019天天干| 日韩视频免费在线| 国产全黄a一级毛片视频| 精品欧美一区二区精品久久| 女警骆冰被黑人调教免费阅读小说| 亚洲综合色丁香婷婷六月图片| 国产精品亚洲а∨无码播放不卡|